The diffusion furnace that could perform the oxidation process is composed of a furnace frame, a heater, a heating control device, a temperature measure device, a quartz furnace tube, a push-pull carrier tray, some gas path, and an exhaust gas treatment device. The temperature control requirements of this kind of diffusion furnaces are as follows:
Heating Temp Range | Ambient-1100℃ | Control Accuracy | ±2℃ |
Max Heating Rate | 15℃/min | Temp Uniformity | ±0.5℃/760mm |
Max Cooling Rate | 5℃/min | Stability | ±0.5℃/24h |
Â
The oxidation diffusion furnace generally uses thermocouples inside and outside the furnace to dynamic control the temperature. Each temperature zone is equipped with one inside and one outside thermocouple to ensure the reliability of the temperature control. S type semiconductor thermocouple(common practice utilizes multi-point thermocouple that has 3-9 different spots to grab temperature info) is often chosen to be the inside thermocouple which is used to sense the temperature of silicon wafer directly, and could translate to precise wafer temperature display.
Â
Products Description
Â
Duchin Instrument developed types of structures for multi-point thermocouple, multi-point thermocouple calibration equipment for experiments, a type of cold-junction structure formulti-point thermocouple, a type of terminal packaging structure for multi-point thermocouple, types of composite metal protection tube of multi-point thermocouple for oxidation furnace, and other proprietary technologies to meet the requirements of diffusion furnace temperature sensing.The technical parameters of the S type semiconductor thermocouple specialized for photovoltaic equipment are as follows:
Technical Parameters | Internal Thermocouple |
Type | S,R |
Wire or MIMS Diameter | φ0.35~0.5 |
Working Temp(℃) | 0~1100 |
Accuracy(℃) | ±1.0 |
Protective Tube Length(mm) | ≤4000 |
Protective Tube Diameter(mm) | φ12~18 |
Protective Tube Material | Quartz |
Hot End Structure | Exposed |
Number of Points | 3~6 Points |
Termination | Small Connector |
Compensation Wire | SC-2×0.5FPF |
Structure Characteristics | To assemble T/C in combination for each point is quite difficult |
Â
Product details
Â
Our Customers
Â
Â
Insights into our company
Â
Â
Insights into our production
Â
Manual Welding
Automatic Welding
Insulation Testing
Laser Marking
Warehouse Managing
Thermocouple Assemble
Vacuum Leak Detection
Surface Polishing
Â
Quality Certifications
Â
http://www.duchinsensor.com/